Quantity
|
Out of stock
|
||
|
Windy Boy Protection Box can do everything: It protects the inverter from excess voltage by feeding excess generator voltage to a load resistor, which slows down the turbine. In addition, the box has a three phase rectifier. It is supplied as a ready unit and can be used with virtually all types of arrays from different vendors in different power classes. Windows, thus, suitable for use with wind plants as well as for other permanent magnet generators such as small hydro power plants and CHP systems.
High dynamic overvoltage protection
optimum start time of a wind turbine
High efficiency integrated inverter
Feed-to-in, even when the excessive voltage array
Easy installation
three-phase connection array
Available in three voltage classes: 400 V, 500 V and 600 V
specifications:
Suitable for - WB 2500 , WB 3000, 5000A, WB 6000A
rectifier - Integrated
Dimensions (L / H / W) - 280/220/130 mm
Weight - kg 5
Number - 1 x
phase AC voltage AC - 3 x 0 V - 500 V
AC - 3 x 0 A - 11,5A
frequency range - 0 Hz - 400 Hz
Rated power - 2 kW - 7 kW
number of phases - 3
limiting voltage (DC) - 600
Total power - 7 kW
Number - 1
Rated voltage (DC) - 600 V RMS power
- 7
Maxim efficiency> 99.95%
loss at continuous power - 30W Ambient temperature -25 ° C ... +60 ° C
Degree of protection (in accordance with IEC 60529) - IP54
Load resistance - optionally
type designation - WBP-Box 600-11