| Quantity | Out of stock | ||
|  | |||
        Power Optimizers SolarEdge Power. . Modulo addition to industrial installations 
 P700 (2 photovoltaic modules 60 elements) 
 
 Specifications: 
 LOG 
 Calculated DC power consumption - 700 W 
 absolute maximum input voltage (open circuit voltage at the lowest temperature) - 125 VDC. Current Work 
 OTMM range - 12.5 - 105 VDC. 
 current maximum continuous input current (short circuit current) - 10.1 A post. 
 Maximum current efficiency - 99.5% 
 average efficiency - 98.6% 
 Overvoltage - II 
 
 EXIT OPERATION DURING (POWER optimizer be connected to an In operating the inverter SOLAREDGE) 
 The maximum output current - 15 A post. 
 current Maximum output voltage - 85 V DC. current 
 
 OUTPUT STANDBY (POWER optimizer disconnect the inverter or inverter SOLAREDGE SOLAREDGE turned OFF) 
 Secure output voltage of the power optimizer - 1B post. current 
 
 
 COMPLIANCE EMC - FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3 
 Security - IEC62109-1 (protection class II) 
 RoHS - Yes 
 Fire safety - VDE-AR-E 2100-712: 2013-05 
 
 SPECIFICATIONS FOR INSTALLATION 
 
 Suitable inverters SolarEdge - Three-phase inverter < br /> The maximum permissible system voltage - 1000 V DC. current 
 Dimensions (LxWxH) - 128 x 152 x 50 mm 
 Weight (including cables) - c 1064 
 inlet connector - MC4 
 output connector - MC4 
 length output wire - 2.1 m (horizontal orientation) 
 Operating temperature range - from -40 - +85 / ° C 
 protection - IP68 / NEMA6P 
 Relative humidity - 0 - 100% 
 
 CONSTRUCTION OF PHOTOVOLTAIC mODULES USING INVERTER SOLAREDGE 
 Suitable optimizers power - P700 
 
 minimum section length: 
 power optimizer - 13 
 Photovoltaic modules - 26 
 maximum section length: 
 power optimizer - 30 
 Photovoltaic modules - 60 
 Maximum power section - 12750 watts 
 Parallel section length or different orientation - Yes 
    
 
                                    