Quantity
|
Out of stock
|
||
|
The heat pump system "air-water" (with integrated tank) AlcAR-05ZB 200L
Nominal conditions hot water:
inlet air temperature - 20C, at a humidity of 59%,
the initial temperature of the heated water - 15C,
water outlet temperature - 55C
Features:
tank capacity, L - 200
indicators:.
generate heat power, KW - 4,8
BTU / H -16480
power consumption, KW - 1,18
Rated current, A - 4,71
COP - 4,1
Max. Rated current, A - 7.5
Electricity, KW / KW - 220V / ~ / 50HZ
noise level, Db (A) - 48
Management:
Temperature range ° .With - ± 1
Throttling (type) - capillary
Refrigerant:
type - R410A
volume, KG - 0.9
Compressor:
type - Rotary
Number of units. -1
air heat exchange zone:
Type - heat exchanger with finned heat transfer surface
Motor Power - 0.03
tank:
Type - Water tank with the pressure resistance
Size inlet piping, inch - 1/2
dimensions of pipelines at the outlet inch -. 3/4
Maximum pressure water side, kpa -. 1000