Quantity
|
Out of stock
|
||
|
Charge Controller Steca PR 1010 10A / 12B / 24B
charge controllers Steca Solar PR applied on small systems from 60 watts to 720 watts. PR series controllers at a current of 10 amperes or more are LCD multi-function display that shows the exact state of charge of the battery (AB) in percentage and visual column. The heart of the controller is an integrated circuit ATONIC © II, which contains a program with an improved self-learning algorithm. The chip can accurately determine the state of charge (SOC), which is the best guarantee for long-life batteries
charge controller Steca PR
* charge technology PWM (PWM - Pulse Width Modulation).
* 3-charge mode: fast (forced) supporting, leveling
* Version: 5, 10, 15, 20 and 30 A 12/24
* Automatic load connection when charging AB
* Temperature compensation
* grounding positive contact (or) grounding the negative terminal at one terminal
* parameter Adjustment buttons 2
* Optional control lighting at night
SPECIFICATIONS:
parameters Operating voltage 12 V or 24 V; automatic determination
voltage range (12) 6.9 - 17.2
voltage range (24) 17.3 - 43
Permitted working temperature range from - 10C to + 50 ° C ° < br /> Authorized storage temperature range from - 20C to + 80 ° C °
12 power consumption: about 12.5 mA; 24: about 15.8 mA
PWM frequency 30 Hz
Maximum Input Voltage 45 V
Battery Undervoltage 6.9
Electrical currents:
Max. A continuous value of 10
current photovoltaic module in the chain
Temperature protection:
Load shedding> 85 ° C
Reactivation load <75 ° C
final charging voltage:
"floating" charge 13.9 / 27.8 In
«Boost" charge; . 2 h 14.4 / 28.8
«Equalization"; . 2 h 14.7 / 29.4 In
30 days of operation; if necessary 14.7 (28.8) (2 h.)
Temperature compensation +/- 4 mV per cell in ° K (the internal sensor built; external temperature sensor is possible as an option)
Activation charging mode controller:
threshold voltage charge mode activation control
«floating" charge> = 12.7 V or> = 25.4 The
«Boost" charge; . 2 hours 11.7 - 12.4V; or 23.4 - 24.8 In
«Equalization"; . 2 hr <11.7; 23.4
30 days of operation; if you want to be activated, if within 30 days there was no mode "boost", "EQ"
Load Off control voltage
Early warning about disabling load <11.7 / 23.4
load shedding <11.1 / 22.2 in
Reconnect load> 12.6 / 25.2 The
Mechanical parameters:
IP 22 protection type
wall Mounting