Quantity
|
Out of stock
|
||
|
Battery charge controller K-08 / 48-5VG / PM (hereinafter - the controller) is used to provide the correct battery charging (hereinafter - AB) from 5 sources, which may be the wind turbine the wind turbine-08/48 (hereinafter - WPU) and the photovoltaic modules (hereinafter -. PEM) with a nominal capacity of up to 800W
controller limits the charging current and voltage AB with regard to its capacitance and temperature. Also takes into account the current load or additional sources connected to controll through the controller.
load switching is not provided. Consequently, the controller does not protect AB deep discharge. This function must be implemented separately (for example - an inverter), or performed manually, or the total power generation sources must be known to greater loads consumption
DELIVERY
controller K-08 / 48-5VG. / FM 1 pc.
meter parameters Mitnija AB-48/300 * 1 pc.
The remote control VCP-48/485 * 1 pc.
Set of connectors for connecting the modules * 1 pc.
passport 1 pc.
Packaging 1 pc.
* available on request
SPECIFICATIONS BATTERY
Type Acid voltage, 48
capacity ACh 300..1000
K-08 / 48-5VG / FM
number of inputs 5
power inputs of 800 W
MINT- 48/300
voltage measuring range, As 20..75
current measurement range, -175 ... 125 A
measuring temperature range, C -55..125
TLU -48/485
power supply, 48
Type RS-485
line length, m up to 1000