Quantity
|
Out of stock
|
||
|
Diameter condenser heat pipe - 24 mm)
collector CRS-A effective for use all year round in any
region of Ukraine. Collector efficiency - 95%. It has high performance in terms of low solar insolation. Insulation of the heat exchanger 75 mm. Aluminum collector frame allows to reduce the load on the supporting structures of the roof. The universal frame structure is designed to fit to any type of collector roof from horizontal to vertical surfaces
Specifications CRS-A:
exchanger (Manifold)
internal heat exchanger Material - Copper <. br /> Diameter of the inner heat exchanger - 38 mm
exchanger wall thickness - 1.5 mm diameter sleeve
exchanger - 24.3 mm depth
sleeve exchanger - 62 mm distance between centers
( tube) - 80 mm
start angle shading (tube) - 86 °
output couplers - 3/4 "wide BP overboard under
union nut
Insulation Material - mineral wool processing vlagoottalkivayuschey
Insulation Thickness - 65-85 mm
outer cover material - aluminum
thickness of the outer coating - 0 2 mm diameter
"nests" vacuum tubes - 63 mm depth
"nests" vacuum tubes - 37 mm Diameter
temperature sensor sleeve - 8 mm
vacuum tube holders - on the latch, with an additional heat exchanger fixing
Color - metallic
temperature sensor location - on both sides
vacuum tube Options Heat pipe:
type vacuum tr to - Heat pipe
condenser diameter - 24.1 mm nickel-plated
capacitor height - 45 mm Diameter
tube heat pipe - 8 mm
Structure --glass tube with a concentric double-walled
glass Quality - borosilicate glass 3.3 (T-0,91)
Exterior tube diameter and wall thickness of 58 +/- 0.7 mm, 2 mm
inner tube diameter and wall thickness - 47 +/- 0.7 mm, 1.6 mm
tube length - 1800 mm (850 mm CRS-VA)
absorption Area - 0.08 m2
aperture size - 0,093 m2
absorbent coating characteristics:
Structurally - laminated (layer 12 c) a solar absorbent coating of Al-N / SS / Cu
coating Method - Direct spraying
radiation absorption> 95% Heat emission
<5% at 80 ° C
vacuum Depth P <3h10-3 Ra
stagnation temperature of 250 ° C
solar power to start efficient heat collection - 0.77 kW / m2
average coefficient of thermal losses - 0.8 W / m2 * by
hail resistance <35 mm
Resistance to overheating - 400 ° C
Resistance to freezing - up to -50 ° C
Resistance to wind - up to 30 m / s < br /> Weight - 2.29 kg +/- 0.18 kg
time for the start - up to 10 min starting evap
ra 30 ° C
Lifetime - at least 15 years
General parameters CRS-A-20 (24 mm):
Number of tubes - 20 pieces
peak. energy - 1376 W x hour
aperture area -1,87 m2
absorption Area - 1.6 m2 capacity heat exchanger
- 2.2 l
Dimensions LxWxH - 2000h1640 mm
Weight - 75 kg