Energy-efficient technologies, time-tested
0
My order

Inverter SMA Sunny central 760 CP SC-10

SKU: tmc0003883
SMA inverter Sunny central 760 CP SC-10. More power: With advanced features, the new SUNNY CENTRAL CP series has become even more effective. SUNNY CENTRAL CP is also optimized for low temperatures to -40 ° C and at full rated power in continuous operation up to 50 ° C.
converter includes all network management functions.
A customized computer platform allows for optimal monitoring and monitoring.
maximum results with low cost system
full rated power in continuous operation at ambient temperature to 50 ° C
optimized for extreme climate conditions from -40 ° C and 62 ° C < br /> Intelligent power management with OptiCool ™
a wide DC input voltage range for flexible use of different modules configurations
All network management features included

specifications:..
Input (DC)
Maxim dc power (COS p = 1) - 853 kW
Maximum Input voltage 1) - 1000/1100 additional
MPP voltage (at 25 ° C / @ 50 ° C at 50 Hz) - 609 V - 820 V / 554 V - 820 V
MPP voltage (at 25 ° C / @ 50 ° C at 60 Hz) - 609 V - 820 V / 554 V - 820 V
Nominal input voltage - 595 V
Maxim input current - 1400
minimum input voltage / VMPP_min in I MPP Number of independent inputs MPP - 1 Number of inputs
DC - 9 / 32 (Optiprotect)

Yield (AC)
Rated capacity (at 25 ° C) / nominal AC power (at 50 ° C) - 836 kVA / 760 kVA
Nominal voltage AC / range - 342 V / 308 V - 376 V
frequencies AC / range - 50 Hz, 60 Hz / 47 Hz ... 63 Hz
rated frequency / voltage - 50 Hz / 342 V
Maxim output current, A - 1411
maximum THD - <3%
The power factor at rated power / shear adjustment factor - 1 / 0.9 overexcitation ... 0,9 underexcited < br /> Phase network - 3/3


efficiency MaksimumEffektivnost / European efficiency / CEC efficiency - 98.6% / 98.4% / 98.5%

Protection
Disconnecting device at the inlet side - a motor-driven switch-disconnector / switch (Optiprotect)
Disconnecting device on the output side - AC breaker
DC overvoltage protection / AC overvoltage protection - surge arrester type I / type I of OPN
network monitoring - yes
ground fault monitoring / remote monitoring of earth fault - optional / Extra .
insulation monitoring - optional
surge for auxiliary supply - yes
protection class (according to IEC 62103) / overvoltage category (according to IEC 60664-1) - I / III

General data
Dimensions (L / H / W) - 2562/2279/956 mm (101/90/38 inches)
Weight - 1800 kg
Operating temperature range - -20 ° C ... +50 ° C
noise - 60 dB (a)
Maximum own consumption (operating) / own consumption (at night) - 1700 W 4) / <100 W
External aux omogatelnoe voltage - 230/400 (3 / N / PE)
Cooling - OptiCool
Protection: Electronics / Area Connection (in accordance with IEC 60529) - IP54 / IP23
Installation - unprotected outdoors
maximum allowable value of the relative humidity (dry) - 15% ... 95%
maximum working height above sea level - 2000 m
air flow - of 3000 m / h

Features
DC connection - annular nozzle / Optiprotect
AC connection - tip annular clamp
Display - optional
communication protocols - Ethernet (optical fiber optional) , Modbus
Sunny String-monitor - RS485 / not required (Optiprotect)
Color of the case, the doors, the base, the roof - RAL 9016/9016/7005/7004
Cates certificates and approvals (more on request) - EN 61000-6-2, EN 61000-6-4, EMV compliance CE compliance, Arrete du 4/23/08, RD 1663/2000, RD 661/2007, BDEW-MSRL / FGW / TR8 6) < br />
type designation - 760CP SC-10
Write the first review
A new review or comment
Sign in with
Rate this item
Send
1.00 UAH
Out of production
Sign in to
see discount

Self-delivery, "UkrPochta", "Nova pochta" or convenient carrier.
Courier in Kiev.

Bank transfer ( our company for VAT )
Cash on delivery
Credit Card in privat24, LiqPay
Through cash or self-service terminal Privatbank

The warranty from the manufacturer between 1 and 5 years.

 

According to the current legislation of Ukraine.

Consultation by phone:

+38 (044) 585-64-94
+38 (097) 585-25-00
+38 (095) 585-25-00
+38 (093) 585-25-00

Up