Quantity
|
Out of stock
|
||
|
TECHNICAL DATA
DATA DC
Maxim. DC voltage (V) +1100
range MPPT at nominal capacity (C) 695 ... 900
range MPPT (V) 695 ... 1.000
Maxim. operating current DC (A) 148
MPP tracker - 1
Inputs DC - 20 hMS4
DATA AC
AC Rated power (kW) 100
Nominal voltage AC (V) 480
voltage range AC (V) 384 ... 576
connection to AC / 3 phase
Rated power factor / range 1 / 0,3i ... 0,3c
rated frequency / frequency range (Hz) 50 65 60/45 ...
Maximum. AC-current (A) 128
AC bolt connection terminal Al / Cu (70 mm ... 240 mm)
CONDITIONS
intellectual active cooling
Maximum. temperature at nominal power (° C) 45
Ambient temperature (° C) - 25 ... + 60
Relative humidity (%) 0 ... 100
Maxim. Height (m asl) 3000
Classification environment (IEC 60721-3-4) 4K4H
inverter type of protection (IEC 60529) IP65 / NEMA 4
security features and pROTECTION
Automatic DC switch - there
insulation monitoring - there
fuses: tsentralnyy- not raspredelennyy- there
grid Monitoring: voltage, frequency, passive and active protection from interference DC fluctuation
monitoring residual current (RCD) is
GENERAL
LED Display Interfaces 2 x Ethernet or 2 x RS485, Bluetooth®, multifunctional DI / DO
Sunspec communication protocols (Modbus TCP, Modbus RTU), USS (Ethernet, RS485)
transducer dimensions H x W x D (mm) 670 x 600 x 330
converter Weight (kg) - 65