Quantity
|
Out of stock
|
||
|
Inverter Pulse IPI- 50V / 3,0kVA
1 Purpose
1.1 Voltage converter 50V DC IPI-50V / 220V 3kVA-50Hz (more - converter) for powering the various electric power receivers consumption to 3000W single phase 220V 50Hz alternating current (rail)
1.2 The converter is designed for continuous clock work indoors under the following environmental conditions:
- ambient temperature from 0 C to 40 C.
- relative humidity to 95% at a temperature of +25 C.
2 basic specifications and characteristics
2.1 Standard value DC supply voltage 50V
2.2. operating voltage range of the DC power supply 48 ... 70V.
2.3 The allowable range of voltage DC power 42 ... 72B.
2.4 nominal value of the output AC voltage 220 (none 5).
2.5 Nominal value h output voltage pilots at 50 (none. 1)
2.6 Hz maximum value of the total load power 3000W
2.7 Operating range of load power of from 0 to 100% of nominal load
2.8 Type -.. Active, active-inductive, capacitive, active- nonlinear (rectifier filter)
2.9 Operating range of load power factor 0.7 ... 1
2.10 overload power factor of 1.5:.. 1 during 5c
2.11 coefficient of sinusoidal distortion. output voltage at rated power active load, not exceeding 10%.
2.12 The current consumed by the converter at nominal input voltage and full load power, not more than 64A.
2.13 converter has an overload protection and short-circuit to the load from low or high input voltage of reverse polarity voltage supply, as well as overheating.
2.14 Automatic disconnection occurs at a converter output voltage beyond the power to admissible range. Automatic activation of the transducer occurs when returning to power supply voltage operating range.
2.15 Dielectric strength between the closed and the input terminals of the converter housing between the closed and the output terminals of the converter housing, and between the closed and the input terminals of the inverter outlet closed, can withstand without breakdown test voltage of 1000 V (effective value).
2.16 Efficiency converter at nominal input voltage and full load power at least
0.88 2.17 Cooling method -. forced ventilation with temperature control of the air supply
2.18 Dimensions converter (WXHXD, without protrusions) 400h100h260mm. .
2.19 converter Weight, 8,0kg.