Quantity
|
Out of stock
|
||
|
1 Purpose
1.1 Voltage converter 110V DC (hereinafter - the converter) IPI.110V / 220V.1,5kVA.50Hz designed to supply power to the receiver power consumption by up to 1500VA (fridge, TV, computer, audio, -videotehnika, food processor, microwave, etc.), single-phase 220V 50Hz AC
1.2 The converter is designed for continuous clock work indoors under the following environmental conditions:..
- ambient temperature environment from 0C to + 40C;
- refers te a humidity to 95% at a temperature of + 25C.
2 basic specifications and characteristics
2.1 Standard value DC power supply voltage 110v.
2.2 Operating Range DC voltage supply (88 ... 150) In.
2.3 Permitted voltage DC power range (82 ... 153) In.
2.4 Standard value AC output voltage (220x2) B.
2.5 The nominal value of the output voltage frequency (50x1) Hz.
2.6 nominal value 1500VA.
load apparent power Engine 2.7 . S load capacity range between 0 and 100% of rated load
2.8 Type - active, active-inductive, capacitive, active-nonlinear (rectifier filter)
2.9 Working range power factor loads 0. . 7 ... 1
2.10 overload power factor of 1.7:. 1 during 5c
2.11 ratio distortion sinusoidal output voltage at rated power active load, not exceeding 10%
2.12 current. consumed by the converter at nominal mains voltage and full load power, not more than 16A.
2.13 converter has an overload protection and short circuit across the load reduced from a high voltage power supply polarity voltage supply connection and also from overheating.
2.14 automatically disabling the inverter occurs when the voltage of the output power range. Automatic activation of the transducer occurs when returning to power supply voltage operating range.
2.15 Dielectric strength between the closed and the input terminals of the converter housing between the closed and the output terminals of the converter housing, and between the closed and the input terminals of the inverter outlet closed, can withstand without breakdown 1000V test voltage (effective value).
2.16 Efficiency converter at nominal input voltage and full load power at least
0.88 2.17 Cooling method -. forced ventilation with temperature control of the air supply
2.18 Dimensions converter (Wxhxd, without protrusions) 305x85x210mm. . Design-table
2.19 converter Weight, 5,0kg.