Quantity
|
Out of stock
|
||
|
Hybrid Infinisolar series inverters -invertory with integrated MPPT charge controller and the ability to give the surplus electricity to the grid. The inverter 2 in 1: network and an autonomous power in one device
• Pure Sine Output
• Power consumption and transmission network
• programmable priority supply of photo module, or battery. network
• user-configurable current battery suitable for different types of batteries
• Programmable modes of operation: network, backup, network to return
• Built-in timer for various mode on / off
• Communicator for USB, RS-232, Modbus and SNMP
• monitoring program to indicate the status in real time and control
• Parallel operation of up to 3 units
specifications:
phase - three phase input / three phase output
Maximum power input to photo module - 14850 watts
calculated output power - 10000 W. Maximum
charge capacity - 9600 W
mains
PV input (DC):
Nominal DC m eye / Maximum DC - 720 V / 900 V voltage
start / start power supply voltage - 320 V / 350 V
voltage range MPP - 400 V 800 V
number of trackers MPP / max input current - 2/2 x 18.6 A
network output (alternating current):
Nominal output voltage - 230 V / 400 V
voltage range at the output - 184 - 265 * per phase
Nominal output current - 14.5 A per phase
power factor -> 0.99
Maximum transfer efficiency (direct current / alternating current) - 96% < br /> European efficiency Vnominal - 95%
Autonomy
Alternating current input:
start voltage / startup voltage - 120 - 140 V per phase / 180 In
acceptable input voltage range - 170 - 280 V per phase
maximum input current - 40 A
PV input (DC):
maximum voltage - 900 In
voltage range MPP - 400 V ~ 800 V
The number of trackers MPP / Maximum th input current - 2 / A 2 18.6
battery operation mode at the output (alternating current):
Nominal output voltage - 230 V / 400 V
waveform at the output - Pure Sine
efficiency (DC to AC) - 91%
PV input (DC):
rated voltage DC / DC maximum voltage - 720 V / 900 In
voltage start / start power supply voltage - 320 V / 350 V
voltage range MPP - 400 V 800 V
number of trackers MPP / maximum input current - 2/2 x 18.6 A < br />
network output (alternating current):
Nominal output voltage - 230 V / 400 V
voltage range at the output - 184 - 265 * per phase
Nominal output current - 14.5 A per phase
Alternating current input:
voltage start / startup voltage - 120 - 140 V per phase / 180V
acceptable input voltage range - 170 - 280 V per phase
maximum alternating input current - 40 A
battery operation mode at the output (alternating current):
Nominal output voltage - 230 V / 400 V
efficiency (DC to AC) - 91%
< br /> battery and charger:
Rated DC voltage - 48 V
Maximum charge current - default 60 A, 10 A - 200 A (configurable)
Physical characteristics :
dimensions L x W x H (mm) - 167.2 x 500 x 622
net Weight (kg) - 45
interface:
communication port - RS -232 / USB, and CAN
Smart slot - Optsionno SNMP, Modbus and AS-400 card
Working conditions:
humidity - 0 ~ 90% RH (non-condensing) < br /> Working temperature - from -10 ° C to 55 ° C
Altitude 0 ~ 1000m