Quantity
|
Out of stock
|
||
|
It is a multifunctional inverter / charger is a portable size that combine the functions of the inverter, solar charger and a battery charger. Its comprehensive LCD display provides the user setting and easy access to the operating buttons such as battery charging current, AC / priority solar charger and a suitable input voltage based on a variety of applications
Features:.
- pure sine wave inverter with
- configurable input voltage range for home appliances and personal computers with the help of the LCD
- configurable battery charging current on the basis of applications via the LCD settings
- configurable AC / priority solar charger by setting the LCD
- is compatible with the mains voltage or generator power
- automatic restart while AC is recovering
- overheating protection / short-circuit protection, overload < br /> - Smart design the charger to optimize battery life
- function cold start
specifications:
Nominal input voltage - 220 Vac
losses low voltage - 170Vac ± 7V (UPS); 90Vac ± 7V (technique)
losses low reverse voltage - 180 VAC ± 7V (UPS);
100VAC ± 7V (technique)
loss high voltage - 280VAC ± 7V
loss of high reverse voltage - 270Vac ± 7V
maximum input voltage of the DC - 300 V
nominal input frequency - 50 Hz / 60 Hz (automatic detection)
Low frequency loss - 40 ± 1 Hz < br /> Low return loss frequency - 42 Hz ± 1
high frequency loss - 65 ± 1 Hz
high return loss frequency - 63 Hz ± 1
output short circuit protection - circuit breaker < br /> Efficiency (Line Mode)> 95%
transmission time - 10 ms typical (UPS); Typical 20 ms (technique)
nominal output power - 3000VA / 2400W
output voltage signal -
Pure Sine Output voltage - 220Vac / 230Vac / 240Vac ± 5%
output frequency - 50 Hz
maximum efficiency - 90%
overload 5s @> 150% load; 10s @ 110% ~ 150% load
Rated voltage DC - 24 V DC voltage
idling - 23.0Vdc
Warning DC voltage low:
@ load <20% - 22.0Vdc
@ load> 20% - 21.4Vdc
low DC warning about restoring a low DC voltage:
@ load <20% - 23.0Vdc
@ load> 20% - 22.4Vdc
The cut-off low DC voltage:
@ load <20% - 21.0Vdc
load @> 20% - 20.4Vdc
regeneration high DC voltage - 31.0Vdc
cutoff DC high voltage - 32.0Vdc
DC voltage accuracy Tokak +/- 0,3% V @ without load
THDV - <3% with linear load, <5% for non-linear loads at nominal voltage
DC Offset - <100mV
no-load power consumption <25W
Saved consumption mode power <10W
charging algorithm - 3-step
charging current AC - 2/10/20/30/40/50/60 Amp (@ VI / P = 230)
MPPT controller solar energy charging mode:
Charging current - 40Amp
MPPT voltage range system - 30V ~ 80VDC
Maxim. voltage system idle stroke - 100Vdc
accuracy DC voltage +/- 0,3%
security certificate - CE
working temperature range from -20 ° C to 55 ° C < br /> storage temperature -30 ° C ~ 60 ° C
Dimensions (LxWxH), mm - 100 x 272 x 355
net Weight kg - 7