SNOPT voltage regulator (R) is designed to provide continuous stabilized voltage of all kinds of electrical load with power supply AC 304B from 80V to stabilize the output voltage accuracy ± 5% with a frequency of 50Hz.
Protects emergency electrical load from the low and high voltage, an overcurrent, over-current, leakage currents in the ground (RCD) in domestic, commercial , industrial premises.
It works on any type of load, are calculated for single-phase electricity line of 220 volt (household and office appliances, electric, gas boilers, air conditioners, refrigerators, welding equipment, and so on.).
Have a multi-level protection energy consumers. In the event of failure in the network or in the load balancer will disconnect the load from the network, and after the elimination of the accident will automatically connect to the network load.
stabilizer SNOPT series voltage (W) is designed for continuous round the clock operation in closed heated facilities.
On all voltage regulators are warranted for 36 months
Scope:.
- for one or a group of consumers with power consumption not polee 1000W
Gazvye boilers.. Coffee machine. Computer and office supplies.
Appliances connected via household voltage stabilizers, working gently and often economical power mode. This allows them to extend the service life and even save on electricity since all home appliances are designed for a specific supply voltage and that at this voltage ensures optimum operation and the highest efficiency
-. To protect the boiler and heating equipment
gas boiler - a complex electrical appliance. Indeed, the boiler equipment, blower burners, water pumps are sensitive to power surges. Therefore, we recommend to protect the boiler to install a voltage regulator
-. For security equipment, alarm and remote control systems
Most electronic security systems allows the voltage deviation of no more than 10%. Our network today such precision is not provided, it leads to a malfunction of the security systems. The voltage stabilizer stabilizes your network and eliminates these problems
-. For a refrigeration and air conditioning
We all know that electric motors do not work under elevated or reduced voltage. They overheat the windings and further release them from the system. Repair of equipment costs about 70% of the cost of new equipment. The voltage stabilizer to protect your equipment from all of the above problems
Specifications:
The input operating voltage, V - 80-304
The output voltage, V - 220
Uin Rated power at 220 kW - 27.5 Maximum power
at Uin. 80B, kW - 10
Maximum power at Ui. 304B, kW - 38
minimum input voltage, V - 80
maximum input voltage V - 304
tripping current circuit breaker, A - 125
A maximum allowable current, no more 30 sec - 160
minimum switching voltage, V - 90
maximum switching voltage, V - 295
deviation from the nominal output voltage at 90-295V Uin - +/- 5%
Number of stages of automatic control - 16
reaction time to changes in the input voltage, ms - 20
protection time voltage, ms - 20
Cutout is lowered to Uin, B - 80
Cutout with an increase Vout to, B - 304
Cutout leakage current during mA - 30,100,300
Cutout with increasing power switches temperature, ° C - 75
Cutout autotransformer with increasing temperature , ° C - 85
protection Level (IP) - IP20
mode - continuous
protection - UHL4.2
Maximum ambient temperature - 40 ° C
Minimum ambient temperature - 1 ° C
Rel. % humidity at ambient temperature - 80 at t 25 ° C
Atmospheric pressure mm.rt. Art. - from 630 to 800
Efficiency, however,% - 95
Weight kg - 92
Overall and installation dimensions, mm - 260h240h460
voltage stabilizer SNOPT (iii) a wide range of working voltage of 80 to 304 V with an accuracy of stabilizing the output voltage of 220V + 5%
Number of steps - 16 (step 10);
range input voltage (Uout at 220 ± 5% In.) - 80-304 V;
Microprocessor control;
LEDs operating modes - a network overload, the RCD, the input voltage is reduced or increased and overheating of the power switches (thyristors) or the transformer;
Digital display operation modes - the time, date, load current (Ampere), the load power (kW) RCD current (mA), the input voltage (volts), the output voltage (V), the temperature of power switches (thyristors) and transformer (° C) and frequency (Hz);
Overheat power switches (Triacs) and a transformer - 46-70 ° C - forced cooling fan with variable speed, 85 ° C - load disconnection (75 ° C - connection);
Connecting to the network - in terminal connection;
Connecting load - in terminal connection;
Hanging Mount;
It is possible to connect the welding equipment;
Color - light gray
The warranty on the voltage regulator with a wide range of voltage - 3 years
.