Quantity
|
Out of stock
|
||
|
The heat pump with the heat source - primer
heat source - primer
Labeling Green iQ
Providing extremely quiet operation of the heat pump via Sound Safe System
system 10 years warranty on the compressor of the heat pump!
Made in Germany
Features labeling Green iQ
provide extremely quiet operation of the heat pump using the Sound Safe system system
The flow temperature to 65 ° C, even at low ambient temperatures (due EVI technology)
high level of efficiency with improved wear-resistant scroll compressor heat pump
material 10 year warranty compressor
features
Highly pumps in the circuit of heating / circulating brine
hot water drain valve
Electric auxiliary heater multistage 9 kW in all models
inrush current limiter
cooling circuit with IC use of sensors and technology EVI
Integrated mode active cold
Embedded standard thermal and electrical counters
* heat pump controller (VRC 700) to be ordered separately!
Specifications VWF 197 / 4
Thermal capacity (B0 / W35 del.T5K 0sogl. EN 14511) 19,7
kW power consumption kW 4,7
conversion factor COP 4,7
sound pressure level at B0 / W35 EN 12102 / EN 14511 in heating mode dB (A) 48,4
Thermal capacity (B0 / W55 del.T8K acc. EN 14511) 20,0
kW power consumption kW 6,6
conversion factor COP 3,2
level The sound power at B0 / W55 EN 12102 / EN 14511 in heating mode dB (a) 48,4
Holodootdacha at A35 / W18 del.T5K active kW 22,3
power consumption kW 6,2
conversion factor COP 3,4
sound pressure level at A35 / W18 EN 12102 / EN 14511 in cooling mode dB (a) 47,2
Eletropitanie control unit V / Hz 230/50
compressor Power / Hz 400/50
Power sub-heater / Hz 400/50
Inrush current limiter 30 a ≤
volume flow in the heating circuit l / h 3320
residual head of the circus. heating pump, del.T = 5K 450 mbar
volume flow in the heat source circuit (brine) l / hr 4780
Residual head circus. heating pump, del.T 3K = 820 mbar
feed the heating circuit temperature (min / max..) ° C 25/65
permissible brine temperature (min / max..)
- in heating mode ° C -10/25
- in cooling mode 0 ° C / 30
Dimensions hydraulic connections "G 11/2"
weight (excluding packaging) 187 kg