Quantity
|
Out of stock
|
||
|
Gas condensation boiler planimetric Viessmann Vitodens 100 W WB1B196 with a mounting frame.
Specifications:
Rated output range when Tv / Tr = 50/30 ^ (o) - 9-26 kW range
rated thermal power at Tv / Tr = 80 / 60 ^ (o) C - 8.2-23.7 kW
pressure of the supplied gas
(natural / nature with gas pressure monitor / liquefied) - 13 / 50mbar
maximum permissible supply pressure
gas (natural / LPG) - 25 / 57.5 mbar
maximum electric power consumption
(including circulator) - 119Vt
permissible operating pressure-
3 bar volume expansion tank - 8 l
maximum working pressure in the hot water line - 10 bar
Continuous output for DHW - 23.7kVt
consumption of water (T = 30K?) - 11.3 l / min
adjustment range DHW temperature - 30-60 ^ (o) C
consumption of natural gas at a maximum nagruzki- 2.6 m3 / h
consumption of liquefied gas at a maximum nagruzki- 1.9 kg / h Diameter
dymohoda- 60 / 100 mm
dimensions ( D / W / H) - 340h400h725
kotla- mm Weight 39 kg
sound pressure-level <45 dB (A)
Max circulating water at T = 20 K - 1018 l < br /> Maximum flow - 10 l / min