Quantity
|
Out of stock
|
||
|
Highly flat collector SPK-F2 Plus ideal for seasonal work at high insolation. Highly selective absorber Almeco-TiNOX (Germany) SPK-F2 Plus collector has a 100% uniform coating across the width of the plate, pogloschyayuschee energy up to 95%, radiant heat energy is not more than 4%. The high thermal stability of the absorber (up to 295 ° C) allows the system to withstand the regimes of stagnation without harm to the collector and the system. Laser welding of copper tubes with the plates of the absorber provides a heavy-duty and complete the assembly of parts. Mounts on any surface. Housing SPK-F2 Plus is made from high quality corrosion-resistant aluminum alloy. The case is assembled without the use of screws and rivets, which ensures reliability and durability.
collector Specifications:
geometric dimensions - 1988h1041h90 mm
housing - Aluminum with electrostatic coating
Net weight - 37.2 kg
Seal - EPDM rubber, silicone gaskets
Gross area - 2.07 m2
aperture area - 1,92m2
absorption area - 1.82 m2
absorber Material - Aluminum plate coated with a selective Almeco-Tinox < br /> absorber Thickness - 0.3 mm
absorption coefficient of absorber - 0.95
reflectance collector (emission) - 0.04
fastening type absorber and a heat exchanger manifold - Laser The volume welding
exchanger manifold - 1.07 l
absorber tube diameter - 8 mm / 10 mm wall thickness
absorber tubes - 0.4 mm
diameter of connecting piping - 18/22
mm wall thickness of the connecting piping - 0.65 mm Number of tubes
absorber - 8 pieces
Step absorber tubes -. 110 mm
the glass material coating - Tempered glass with low iron content < br /> Throughput capacity glass - 0.91
glass Thickness - 4 mm
Insulating material housing - wool
Thermal conductivity - 0.037 W / (m x K)
Teploemkos be glass wool - 0.84 kJ / (kg x K)
density glass wool - 52 kg / m3
glass thickness - 40/20 mm
stagnation temperature - 194 C. The maximum operating
pressure - 10 bar
Test pressure - 25 bar
Nominal flow - 105 liters / hour
mounting method - on a horizontal surface, on an inclined roof,
incorporation into roof. Peak power
* - 1448 W
Optical efficiency - 75.4% **
temperature coefficient - ** 4.255 W / (m2 x K)
temperature coefficient - 0.027 ** W / (m2 x K2)
collector Performance **
temperature difference / power - 0 R / 1448 W, 10 C / 1365 W, 30 C / 1198 W, 50 C / 1026 W, 70 C / 850 W
* when insolation W = 1000 W / m2
** data confirmed the test protocol SolarKeymark