WINDY BOY 5000A
most optimal and high priborovy systems higher than 5 kV
Windy Boy 5000A have an efficiency of 96.1%, and also suitable for the development of a three-phase network from the wind power. Complex SMA Power Balanser will deter the excessive unbalance load, and in addition, the installation has the capability to feed the load even if the individual phases are turned OFF. Die-cast aluminum, and a wide operating temperature range allows the inverter almost anywhere, and thanks to the cooling system OptiCool, the equipment is operated at ambient temperatures up to 45 ° C with maximum efficiency
features / advantages:.
- Up 96.1% efficiency
- Ability to build three phase systems up to 18 kW
- Integrated SMA Power Balanse
- Advanced Turbine mode
- Compatible with SMA Sunny Boy
- Available customizable U / I characteristic output
- Galvanic isolation transformer
- Integrated 2-line display
- finding and communicating with a display, network and the signals along the cable (RS232 or RS485)
- Compatible with Windy Boy Protection Box 600
- Independent disabling device on DIN VDE 0126 -1-1
- efficient cooling system OptiCool
- Extended temperature range from -25 ° C to +60 ° C
specifications Input (DC) < br /> Max. power 5750 W
The recommended power 2500 hours of full load / year 4600 W
The recommended capacity of 5000 hours of full load / year 4200 W
Max. DC voltage of 600 V
input voltage for «Turbine Mode» 246 V - 600 V
Min. input voltage to activate «Turbine Mode» 250 V
Maks.vhodnoy current 26 A
Yield (AC)
Nominal power AC 5000 W
Max. AU cardinality 5500 W
Max. output current of 26 A
nominal AC voltage / Area 220 V - 240 V / 180 V - 260 V
network frequency AC / area 50 Hz / 60 Hz / ± 4.5 Hz
Power Factor 1
Accession single phase AC
efficiency
Max. Efficiency 96.1%
Euro ETA 95.2%
Safety DC-control
yes Short-circuit protection for AC yes
ESS- short-circuit control on the ground so
Network monitoring and
Integrated DC and AC current and
General data length / width / height in millimeters of 468/613/242
Weight 62 kg
Operating temperature -25 ° C ... +60 ° C
consumption: work (Standby) / night <7 W / 0.25 W
Topology LF transformer
cooling program OptiCool
installation location: Indoor / outdoor Equipment
DC-connection MC4
AC-prisoedenenie clip
Graphic yes
display Interfaces: Bluetooth / RS485 option