Quantity
|
Out of stock
|
||
|
converter includes all network management functions.
A customized computer platform allows for optimal monitoring and monitoring.
maximum results with low cost system
full rated power in continuous operation at ambient temperature to 50 ° C
optimized for extreme climate conditions from -40 ° C and 62 ° C < br /> Intelligent power management with OptiCool ™
a wide DC input voltage range for flexible use of different modules configurations
All network management features included
specifications:..
Input (DC)
Maxim dc power (COS p = 1) - 808 kW
Maximum Input voltage - 1000/1100 additional
MPP voltage (at 25 ° C / @ 50 ° C at 50 Hz) - 577 V - 820 V / 525 V - 820 V
MPP voltage (at 25 ° C / @ 50 ° C at 60 Hz) - 529 V - 820 V / 505 V - 820 V
Nominal input voltage - 565 in
Maxim input current - 1400 a
minimum input voltage / VMPP_min in I MPP
Number DC inputs - 9 / 32 (Optiprotect)
Yield (AC)
Rated capacity (at 25 ° C) / nominal AC power (at 50 ° C) - 792 kVA / 720 kVA;
Nominal voltage AC / range - 324 V / 292 V - 356 V;
frequencies AC / range - 50 Hz, 60 Hz / 47 Hz ... 63 Hz;
rated frequency / voltage - 50 Hz / 324 V;
Maxim output current, A - 1411;
maximum THD - <3%
The power factor at rated power / adjustable shift factor - 1 / 0.9 ... overexcitation 0.9 underexcited;
network Phase - 3/3;
efficiency Maximum efficiency / European efficiency / CEC efficiency NOSTA - 98.6% / 98.4% / 98.5%;
Protection
Disconnecting device at the inlet side - a motor-driven switch-disconnector / switch (Optiprotect); < br /> Disabling device on the output side - AC circuit breaker;
DC overvoltage protection / AC overvoltage protection - arrester type I / type arrester I;
network monitoring - yes;
monitoring faults ground / Remote monitoring of earth faults - optional / Supplementary .;
insulation monitoring - optional;
surge for auxiliary supply - yes;
protection class (according to IEC 62103) / overvoltage category (in according to IEC 60664-1) - I / III;
General data
Dimensions (L / H / W) - 2562/2279/956 mm (inch 101/90/38) < br /> Weight - 1800 kg
temperature range -20 ° C ... +50 ° C
noise - 60 dB (a)
Maximum own consumption (operating) / own consumption (night) - 1700 W 4) / <100 W
external auxiliary voltage - 230/400 (3 / N / PE)
Cooling - OptiCool
Protection: Electronics / Area Connection (in accordance with IEC 60529) - IP54 / IP23
Installation - unprotected outdoors;
maximum allowable value of the relative humidity (dry) - 15% ... 95%
maximum working height above sea level - 2000 m
consumption air - 3000 m z / h
Features
DC connection - annular nozzle / Optiprotect
AC connection - tip annular clamp
Display - optional communication protocols
- Ethernet (optical fiber optional), Modbus
Sunny String-monitor - RS485 / not required (Optiprotect)
Color of the case, the doors, the base, the roof - RAL 9016/9016/7005/7004
Cates certificates and approvals (more on request) - EN 61000-6-2, EN 61000-6-4, EMV compliance CE compliance, Arrete du 4/23/08, RD 1663/2000, RD 661/2007, BDEW-MSRL / FGW / TR8 6)
type designation - 720CP SC-10