converter includes all network management functions.
A customized computer platform allows for optimal monitoring and monitoring.
maximum results with low cost system
full rated power in continuous operation at ambient temperature to 50 ° C
optimized for extreme climate conditions from -40 ° C and 62 ° C < br /> Intelligent power management with OptiCool ™
a wide DC input voltage range for flexible use of different modules configurations
All network management features included
specifications:..
Log (DC)
Maxim dc power (COS p = 1) - 713 kW
Maximum Input voltage - 1000/1100 additional
MPP voltage (at 25 ° C / @ 50 ° C at 50 Hz) - 529 V - 820 V / 500 V - 820 V
MPP voltage (at 25 ° C / @ 50 ° C at 60 Hz) - 529 V - 820 V / 505 V - 820 V
Nominal input voltage - 550
Maxim input current - 1350 a
minimum input voltage / VMPP_min in I MPP
DC - 9/32 (Optiprotect)
Yield (AC)
Rated capacity (at 25 ° C) / nominal AC power (at 50 ° C) - 700 kVA / 630 kVA < br /> Rated voltage AC / range - 315 V / 284 V - 347 V;
frequencies AC / range - 50 Hz, 60 Hz / 47 Hz ... 63 Hz;
rated frequency / voltage - 50 Hz / 315 V;
Maxim output current, A - 1283;
maximum THD - <3%
The power factor at rated power / adjustable shift factor - 1 / 0.9 overexcitation. ..0,9 underexcited;
network Phase - 3/3;
efficiency Maximum efficiency / European efficiency / CEC eff ciency - 98.7% / 98.5% / 98.5%;
Protection
Disconnecting device at the inlet side - a motor-driven switch-disconnector / switch (Optiprotect); < br /> Disabling device on the output side - AC circuit breaker;
DC overvoltage protection / AC overvoltage protection - arrester type I / type arrester I;
network monitoring - yes;
monitoring faults ground / Remote monitoring of earth faults - optional / Supplementary .;
insulation monitoring - optional;
surge for auxiliary supply - yes;
protection class (according to IEC 62103) / overvoltage category (in according to IEC 60664-1) - I / III;
General data
Dimensions (L / H / W) - 2562/2279/956 mm (inch 101/90/38) < br /> Weight - 1800 kg
temperature range -20 ° C ... +50 ° C
noise - 60 dB (a)
Maximum own consumption (operating) / own consumption (night) - 1700 W 4) / <100W
external auxiliary voltage - 230/400 (3 / N / PE)
Cooling - OptiCool
Protection: Electronics / Area Connection (in accordance with IEC 60529) - IP54 / IP23
Installation - Unprotected outdoor;
The maximum permissible value of the relative humidity (non-condensing) - 15% ... 95%
Maximum operating altitude - 2000 m
air flow - of 3000 m / h
Features
DC connection - annular nozzle / Optiprotect
AC connection - tip annular clamp
Display - optional
communication protocols - Ethernet (optical fiber optional), Modbus
Sunny String-monitor - RS485 / not required (Optiprotect)
The color of the body, doors, base, roof - RAL 9016/9016/7005/7004 < br /> Cates certificates and approvals (more on request) - EN 61000-6-2, EN 61000-6-4, EMV compliance CE compliance, Arrete du 4/23/08, RD 1663/2000, RD 661/2007, BDEW-MSRL / FGW / TR8 6)
Type designation - 630CP SC-10