Quantity
|
Out of stock
|
||
|
Simplicity. Flexibility
-. Simplified system design due to the double MPPT input voltage and a wide range of up to 1000
- Free choice of sites thanks to IP65
- The parameter settings and the country code during the initial start-up
Open. Interactivity
-. The choice of interface - Ethernet and RS485 for flexible configuration and monitoring
system
- Multilingual 3,5 "TFT LCD screen
- Easy key operating platform
- Digital inputs for connection of economic control receiver
- Adjustable multi-function relay output
efficiency Guarantee
-.. High performance with maximum efficiency> 98%
- Safe operation thanks to the integrated switch AC / DC and AC / DC overvoltage protection
- Standard warranty 5 years
specifications:
Input DC:
Max power DC.. (cos f = 1), the total I / MPP input - 26300Vt / 13200Vt
maximum input voltage - 1000V
MPP voltage range / nominal input voltage - 440V - 800V / 620V
minimum input voltage / initial input voltage of - 250 V / 300 V
Max input current input A / input B -. 3030 Mack A
from. the input current to the input line of the input A / input B - 11,5A / 11,5A
Number of independent MPP inputs / input strings MPP - 2/1 (without String Monitoring Unit) / 2/3 (with String Monitoring Unit)
output AC:
Rated power (230V / 50Hz) - 25000 watts
Maximum AC power - VA 25000
Nominal voltage AC / range - 3 / N / PE, 230, 400V / 180V - 277V per phase
frequency AC / range - 50 Hz, 60 Hz / 45 Hz - 55Hz, 54Hz - 66Gts
nominal mains voltage / nominal network frequency - 230 V / 50 Hz
maximum output current of - 36.5 A
power factor at rated power - 1
offset power factor adjustment - 0.8 conducting - 0.8 lag
flow in phases / phase soedienie - 3/3
Efficiency:
Max. efficiency / European weighted efficiency - 98,3% / 97,8%
Safety devices:
DC isolator / isolator AU - additional. function / ext. function
discharge unit Type II DC / AC - extra. function / ext.
function monitoring unit / fuses - extra. function / ext.
function monitoring ground fault / Network Monitoring - standard feature
Reverse polarity protection DC / AC short circuit the possibility - a standard feature
Galvanic isolation - no
Monitoring sensitive to all the poles residual current - standard function
protection (in accordance with IEC 62103) /
overvoltage category (according to IEC 60664-1) - I / II (DC), III (AC)
General data:
dimensions (W / H / D) - 600/880/249 mm
weight - 59 kg
working temperature range from -25 ° C ... +60 ° C
noise (typical) <57 dB
Power consumption (at night) <5W
Topology - Transformerless
Cooling - fan
degree of protection (in accordance with IEC 60529) - IP65
maximum humidity (no condensation) - 95%
Features:
Connecting DC / AC connection - Multi-Contact MC4, Amphenol MC4, Screw clamp / screw terminals
Display - 3,5 "TFT LCD
interface: RS485 / Ethernet - a standard feature
Multifunction relay / digital input - 3/4
Warranty: 10 years
Approvals ( additional on-demand) - CE, BDEW, VDE 0126-1-1, G59 / 2, EN 61000-3-11 / 12, EN 61000-6-1 / 2/3/4,
IEC 62109-1 / 2, VDE AR-N4105, CEI 0-21, CEI 0-16, AS 4777.2 / 3,
AS 3100: 2009, C10 / 11, EN 50438, UTE C15-712-1, IEC 62116, IEC 61727