Quantity
|
Out of stock
|
||
|
1 Purpose
1.1 Voltage converter 24V DC IPI.24V / 220V.1,5kVA.50Hz current (hereinafter - the converter) designed receivers for feeding power to the power consumption to 1500VA single phase 220V 50Hz AC
1.2 converter is designed for continuous clock work indoors under the following environmental conditions:
- ambient temperature from 0C to + 40C;.
- relative humidity to 95% at a temperature of + 25C
2 basic specifications and characteristics
2.1 nominal value voltage DC power 24,0V current..
2.2 Working voltage DC power range (24.0 ... 30.0) In.
2.3 Permitted voltage DC power range (21.0 ... 32.0) In.
2.4 Nominal value of the AC output voltage (220 4).
2.5 nominal frequency . S output voltage (1 50)
2.6 Hz Nominal value of the total load power 1500VA
2.7 Operating range of load power of from 0 to 100% of nominal load
2.8 Type -.. Active active . -induktivnaya, the active capacitance, nonlinear (rectifier filter)
2.9 Work load power factor range 0.7 ... 1
2.10 overload power factor of 1.7:. 1 during 5c
2.12 The current consumed by the converter at nominal input voltage and full load power, not more than 75A.
2.13 converter has a protection from overload and short circuit across the load reduced from a high voltage power supply polarity voltage supply connection and also from overheating.
2.14 automatically disabling the inverter occurs when the voltage output Nia power of range. Automatic activation of the transducer occurs when returning power within the operating range.
2.15 Dielectric strength between the closed and the input terminals of the converter housing between the closed and the output terminals of the converter housing, and between the closed and the input terminals of the inverter outlet closed, can withstand without breakdown test voltage of 1000 V alternating current frequency of 50 Hz (effective value) in the for 1min.
2.16 Efficiency converter at nominal input voltage and full power of the load, at least
0.85 2.17 Cooling method -. forced ventilation with temperature control of the air supply
2.18 Dimensions converter (Wxhxd, without protrusions) 305x85x210mm. .
2.19 converter Weight, 5,0kg.