UPS Stark Country 5000 INV-PWM 4000Вт 48V

SKU: tmc0005267
. Uninterruptible Power Stark Country INV 5000, with long reservation

TECHNICAL ADVANTAGES:
- Backup Capability load more than 24 hours
- Inverter with pure sine wave
- Selectable charging current
- Availability of controller for solar panel
- protection against deep discharge battery
- LCD-display
- Wall mounting

APPLICATION:
- Uninterruptible power supply of country houses, including
boiler equipment - Computers & Networking
-
Telecommunications - alarm and security system

SPECIFICATIONS:
SPECIFICATIONS:
1) mode of operation with the network specifications:
Form input voltage - sinusoidal (or network generator)
input voltage - 230V
minimum off voltage - 170V + / - 7B (UPS); +/- 7B 90B (consumers)
minimum turn-on voltage - 180V +/- 7V (UPS); 7B +/- 100V (consumers)
Maximum off voltage - 280V +/- 7B
maximum switching voltage - 270V +/- 7B
maximum input voltage - 300V
input frequency - 50Hz / 60Hz (autodetect)
minimum off frequency - 40 +/- 1Hz
minimum switching frequency - 42 +/- 1Hz
Maximum off frequency - 65 +/- 1Hz
Maximum switching frequency - 63 +/- 1Hz
protection against short-circuit at the output - the circuit breaker
Efficiency raborty network - greater than 95% (active load, the battery is charged)
delay - 10 ms (UPS ); 20mm (consumers)
Reduced output - with decreasing input voltage decreases output power

2) Characteristics autonomous mode:
nominal capacity - 5kVA / 4KW
Form output voltage -
pure sine wave output voltage - 230V +/- 5%
output frequency - 50 Hz
Efficiency - 90%
overload - 5c at more than 150% load, 10c at 110% -150% load
maximum power - 2 nominal power during 5c ​​
DC voltage - 48V
idle start voltage - 46,0V

Undervoltage warning:
- load is less than 20% -44,0V
- load more than 20% but less than 50% - 42,8V
- load more than 50% - 40,4V
< br /> Minimum warning off voltage:
- load is less than 20% - 46,0V
- load more than 20% but less than 50% 44,8V
- load greater than 50% - 42,4V

minimum shutdown voltage:
- load varied he longer 20% - 42,00V
- load more than 20% but less than 50% - 40,8V
- load greater than 50% - 38,4V
maximum switching voltage - 58B
Maximum off voltage - 60V
consumption without load - less than 50W
consumption in standby mode - less than 15W

3) charging mode Features:
process charge - three step < br /> charge from the network:
consumption current inverter - 20 / 30A (for U = 230V)
voltage of the main charge:
- a liquid electrolyte - 58,4V
- AGM / GEL - 56,4V
the float voltage - 54V
charge of PV modules:
charge current (PWM) - 50A
battery voltage -48V
range of operating voltages - 60-72V
maximum open circuit voltage - 90V
consumption in standby mode - 2W
voltage tolerance - +/- 0.3%

Main characteristics:
security certificate - CE
Operating temperature - 0 ° C - 55 ° C
storage temperatures - minus 15 ° C - 60 ° C
Dimensions (LxWxH) mm - 120h295h468
Net Weight Kg - 9.8 *

* The weight given without battery
** Battery (s) are optional

Rechargeable **
battery rated battery voltage, V - 48
Number of series-connected 12V batteries pieces - 4
maximum charging current, A - 20/30
battery capacity Ah - up 600

Environmental Parameters:
permissible operating temperature, ° C - 0 to + 55
Allowable storage temperature, ° C - from minus 15 to + 60
permissible relative humidity,% - 5-95 (non-condensing)

ESTIMATED TIME IN VIEW OF battery efficiency INVERTER 0,85
load 500 W:
4h100a / h - 7,5ch.
4h200a / h - 16h.
2h4h200a / h - 33h.
3h4h200a / h - 48h

The load 1000 W:
4h100a / h - 3 h.
4h200a / h - 7h.
2h4h200a / h - 16h.
3h4h200a / h - 24h

The load 2000 W:
4h100a / h - 1.5 hours.
4h200a / h - 3 h.
2h4h200a / h - 7h.
3h4h200a / h - 12h

load 3000 W:
4h100a / h - 50 min.
4h200a / h - 2h.
2h4h200a / h - 4,5ch.
3h4h200a / h - 7h

The load 3500 W:
4h200a / h - 1.5 hours..
2h4h200a / h - 3 h. .
3h4h200a / h - 6h

Connect PV modules (only for models with a charge controller)

NOTE: Set a separate isolating device before connecting the PV modules with overload protection between PV modules and the inverter.

NOTE! All wiring must be performed by qualified personnel.

NOTE! For safe and efficient operation of the system using a special cable for PV modules. The cross section of the cable must comply with the following:
current - 50A
Cable - 1 X 6
Torque - 1.4 - 1.6 Nm
When selecting PV modules make sure that they comply with the following requirements:
1. Load voltage PV modules of the array must not exceed the maximum value of the idle inverter circuit voltage
power inverter -. 5kVA
charging current - 50A
battery voltage - 248B
operating voltage range - 60 ~ 72V
Max. cold stress. stroke - 105B
2. maximum output voltage (Umpp) PV modules must be equal to the optimal Umr or enter Ump range for better performance. This requires a station with several serially connected modules
Model -. 5kVA
Optimum Ump - 60V
Range Ump - 56B ~ 72B
Write the first review
A new review or comment
Sign in with
Rate this item
Send
38 073.00 UAH
В наличии
Sign in to
see discount

Self-delivery, "UkrPochta", "Nova pochta" or convenient carrier.
Courier in Kiev.

Bank transfer ( our company for VAT )
Cash on delivery
Credit Card in privat24, LiqPay
Through cash or self-service terminal Privatbank

The warranty from the manufacturer between 1 and 5 years.

 

According to the current legislation of Ukraine.

Consultation by phone:

+38 (044) 585-64-94
+38 (097) 585-25-00
+38 (095) 585-25-00
+38 (093) 585-25-00

Features
Electric power, W 4000
Price 38073.00
Up