Quantity
|
Out of stock
|
||
|
In the living room you have enough space and you want to ensure the absolute and supreme comfort of hot water? Then you should compose your boiler with a boiler indirect heating.
The heat loss from our hot water boilers with high quality insulation is minimal, and your service boilers square and round profile of different sizes.
The tank should be chosen depending on the number of family members and your individual needs for comfort
systems solar collectors are designed for hot water using free solar energy. The use of solar energy - a big and important step in the future. BOSCH Solar collectors allow the best use of the available energy from the sun. A lot of accessories make it possible to equip solar panels as a single-family homes and facilities with a large consumption of hot water
The bivalent boilers of indirect heating systems for solar collectors
Description:.
boiler indirect heating system for solar collectors with enamelled steel tank and thermal insulation
Model 364l
exchanger Two: top - loop boiler or other primary heat source; bottom - solar circuit
Connecting the heating water and DHW behind
Purpose:
Designed to work in the solar hot water system for domestic purposes for large and medium hot water consumption for residential buildings.
Technical equipment:
corrosion protection using a magnesium anode
isolation on all sides of the rigid foam not containing fluorocarbons and chlorofluorocarbons
Connecting recirculation line
Built cylinder temperature sensor (NTC) with connector
Coupling Rp 1,1 / 2 c stopper for heating element
upper boiler heat exchanger (coil ) - additional heating
maximum power of the heating surfaces at tV = 90 ° C and tSp = 45 ° C, 36.8 kW
maximum power of the heating surfaces at tV = 85 ° C and 60 tSp = 25.5 kW
Maximum operating performance tV = 85 ° C and tSp = 60 ° C 624 l / h
Maximum operational performance tV = 90 ° C and tSp = 45 ° C, 891 l / h
power factor tV = 90 ° C (Max. DHW capacity) 2.5 NL
volume boiler for boiler
Useful volume boiler 364 l useful volume
boiler without heat from the solar collector 150
l useful volume of hot water at 60 ° tsp = tz = C and 45 ° C 164 l
Lower heat exchanger (serpentine) - the solar collector circuit
maximum power of the heating surfaces at tV = 90 ° C and tSp = 45 ° C, 60.1 kW
Backing power consumption (24h) 2.6 kW / day
Dimensions Weight 185 kg.