The main purpose is to compensate UKRM setting the reactive component of the power consumed by the connected equipment (usually electric motors, infectious furnace lyumnistsentnye lamp and DR). Condensing units are manufactured in a metal housing attachments or floor type. It is also particularly powerful unit with high weight are manufactured in frame cabinets with a powerful body. Cabinets are powder painted, which provide reliable long-term protection of painted surfaces from corrosion, giving them not only a great appearance, but they also reduce the costs of coloring products and reduce the damage to the environment. When this metal housing UKRM plants intended for use in an environment characterized as unfavorable, can be painted using extremely resistant special dyes. Fitting overlooking climatic UHL most suitable for most regions of Ukraine, if necessary, can be manufactured with high demands on resistance to moisture and dust (e.g., even with a degree of ingress protection IP54).

When selecting capacitor bank is important to define the degree of equipment protection. If the installation operation is planned for the street, the degree of protection IP54 the installation is to be, in this case require the use of additional ventilation units and seal housing. The plants manufactured by us UKRM apply only reliable capacitors, such as produced by the following manufacturers:

Czech producer of «ZEZ SILKO» (CSADG series capacitors, CSADP);
German company «Electronicon» .;
Slovenian company «Etimat» (LPC series capacitors)
in particular, the LPC capacitors produced in the Republic of Slovenia have the following technical parameters:
1) Un rated working voltage of 400 V and 440 V (the voltage on the capacitors 460, 480, 525, 690 are made only for special order);
2) nominal operating frequency: 50 Hz;
3) the deviation of the nominal capacitance values: - 5% ... +15%;
4) dielectric loss: less than 0.2 W / kvar;
5) total loss: less than 0.5 W / kvar;
6) protection shell : IP 20
7) capacitors correspond to the following standard: IEC 60831-1 and IEC 60831-2;
8) safety parameters: have a self-healing, provided with disconnectors Telem preventing occurrence of excessive pressure;
9) The dielectric material used: polypropylene film;
10) impregnating oil-filled capacitors: vegetable oil, not containing polychlorinated biphenyls;
11) Operating Temperature capacitors -25 , 0 ° C ... + 55,0 ° C;
12) temperature storage capacitors: -40,0 ° C ... + 70,0 ° C;
13) permissible overload 8 hours / day, if the operating voltage exceeds the nominal 10%, and / or the operating current exceeds 30% of the current value Ir (nominal);
14) starting current (for oil-filled capacitors) may be greater than 100 times the value Ir;
15), the starting current for capacitors KNK series 9053: can 130 times the Ir;
16) tests, which are subject to the capacitors for 2 seconds:
• between the layers - the influence of the AC voltage 2.15 times exceeding Un,
• between the layers and the housing - the influence of the AC voltage of 3.6 kV

The work associated with setting UKRM not. necessity of frequent switching of capacitor banks, that is capable of causing large currents (sometimes in excess of almost 250 times In). Therefore, the capacitor switching circuits using special starters, which have great performance. We use in the manufacture of contactors Rade koncar (CNNK), ETI (CEM CN), etal (PML). In plants UKRM uses microprocessor-based controllers type «Novar» kmb systems Czech Republic. In this application, technical solutions and components allow to provide an automatic control switching of capacitor banks, and therefore the power factor of the power system, realizing the most efficient use of the established high and low voltage capacitors. The number of capacitors, their type and denomination, as well as other equipment for each step are selected in step matching parameters which must have a specific installation UKRM

Condenser installations have several advantages:.
A) ease of installation ;
b) the high quality of the equipment;
B) individual selection of equipment by measuring, or by hourly schedule electricity metering;
d) low operational costs;
D) short-term production (5 days).

type capacitor unit UKRM 0.4 / 700/14/25
1. Power and control stage 440 kVar, 12 degrees (25 + 25 + 11 * 50 + 100);
2. Main switch Apator - (Poland);
3. Regulator Novar (Czech Republic);
4. Capacitors ETI (Slovenia);
5. Contactor Rade Koncar (Macedonia);
6. levels of protection - ETI fuses;
7. Housing metal;
8. Dimensions (about) 1800 * 800 * 900 mm
9. Weight 380 kg .;
10. forced ventilation unit;
11. Service life - 15 years;
12. Warranty 1 year.

Production time 14 days. Payment of 50% of the order, 50% ready for shipment
Write the first review
A new review or comment
Sign in with
Rate this item
Send
151 475.00 UAH
В наличии
Sign in to
see discount

Self-delivery, "UkrPochta", "Nova pochta" or convenient carrier.
Courier in Kiev.

Bank transfer ( our company for VAT )
Cash on delivery
Credit Card in privat24, LiqPay
Through cash or self-service terminal Privatbank

The warranty from the manufacturer between 1 and 5 years.

 

According to the current legislation of Ukraine.

Consultation by phone:

+38 (044) 585-64-94
+38 (097) 585-25-00
+38 (095) 585-25-00
+38 (093) 585-25-00

Features
Price 151475.00
Up