UPS Stark Country 2000 INV-PWM 1600W 24V

SKU: tmc0005265
Uninterruptible power Stark Country INV 2000, with long reservation

TECHNICAL ADVANTAGES:.
- Backup Capability load more than 24 hours
- Inverter with pure sine wave
- Selectable charging current
- Availability of controller for solar panel
- protection against deep discharge battery
- LCD-display
- Wall mounting

APPLICATION:
- Uninterruptible power supply of country houses, including boiler equipment
- Computers & Networking
- Telecommunications
- Accidents Naya alarm and security system

SPECIFICATIONS:

1) Performances of the operation to the network:
Form input voltage - sinusoidal (or network generator)
Input voltage - 230V
minimum off voltage - 170V +/- 7V (UPS); +/- 7B 90B (consumers)
minimum turn-on voltage - 180V +/- 7V (UPS); 7B +/- 100V (consumers)
Maximum off voltage - 280V +/- 7B
maximum switching voltage - 270V +/- 7B
maximum input voltage - 300V
input frequency - 50Hz / 60Hz (autodetect)
minimum off frequency - 40 +/- 1Hz
minimum switching frequency - 42 +/- 1Hz
Maximum off frequency - 65 +/- 1Hz
Maximum switching frequency - 63 +/- 1Hz
protection against short-circuit at the output - the circuit breaker
Efficiency raborty network - greater than 95% (active load, the battery is charged)
delay - 10 ms (UPS ); 20mm (consumers)
Reduced output - with decreasing input voltage decreases output power

2) Characteristics autonomous mode:
nominal capacity - 2kVA / 1,6kVt
output waveform -
pure sine wave output voltage - 230V +/- 5%
output frequency - 50 Hz
Efficiency - 90%
overload - 5c at more than 150% load , 10c at 110% -150% load
maximum power - 2 nominal power during 5c ​​
DC voltage - 24V
idle start voltage - 23,0V

Ming mal voltage warning:
- load is less than 20% - 22,0V
- load more than 20% but less than 50% - 21,4V
- load more than 50% - 20,2V

The minimum trip voltage warning:
- load is less than 20% - 23,0V
- load more than 20% but less than 50% - 22,4V
- load more than 50% - 21,2V

minimum shutdown voltage:
- load is less than 20% - 21,0V
- load more than 20% but less than 50% - 20,4V
- load more than 50% - 19,2V
Maximum switching voltage - 29V
Maximum off voltage - 31V
consumption without load - less than 20 W
Consumption in standby mode - less than 10W

3) charging mode Features:
Process charge - three step
charge from the network:
consumption current inverter - 20 / 30A (at U = 230V)
voltage of the main charge:
- a liquid electrolyte - 29,2V
- AGM / GEL - 28,2V
the float voltage - 27V
charge of PV modules:
charge current (PWM) - 50A
battery voltage - 24V
range of operating voltages - 30-32V
maximum open circuit voltage - 60V
consumption standby - 2W
voltage tolerance - +/- 0.3%

Main characteristics:
C Safety rtifikat - CE
Operating Temperature - 0 ° C - 55 ° C
Temperatures Storage - minus 15 ° C - 60 ° C
Dimensions (LxWxH), mm - 100h272h355
Weight net kg - 6,4 *

* Weight shown without battery
** battery (s) are optional

battery **
Rated battery voltage, - 24
number series-connected 12V batteries pieces - 2
maximum charging current, A - 20/30
battery capacity Ah - 600

Environmental Parameters:
The permissible operating temperature, ° C - 0 to +55 Permissible
Storage Temperature, ° C - from minus 15 to + 60
permissible relative humidity,% - 5-95 (non-condensing)

ESTIMATED TIME IN VIEW OF battery efficiency INVERTER 0.85
load 500W:
2h100a / h - 3 h.
2h200a / h - 7h.
2h2h200a / h - 16h.
3h2h200a / h - 24h

The load 1000 W:
2h100a / h -1,5ch.
2h200a / h - 3 h.
2h2h200a / h -7ch.
3h2h200a / h -12ch

load 1500 W:
2h100a / h -50 min
2h200a / h - 2h..
2h2h200a / h -4,5ch.
3h2h200a / h -7ch

Connect PV modules (only for models with a charge controller)

NOTE: Set a separate disconnecting device with overload protection between the PV modules Before connecting the PV modules and the inverter.

NOTE! All wiring must be performed by qualified personnel.

VNIMANIK! For safe and efficient operation of the system using a special cable for PV modules. The cross section of the cable must comply with the following:
current - 50A
Cable - 1 X 6
Torque - 1.4 - 1.6 Nm
When selecting PV modules make sure that they comply with the following requirements:
1. Load voltage PV modules of the array must not exceed the maximum value of the idle inverter circuit voltage
power inverter -. 2kVA
charging current - 50A
battery voltage - 24V
operating voltage range - 30 ~ 32B
Max. cold stress. stroke - 60V
2. maximum output voltage (Umpp) PV modules must be equal to the optimal Umr or enter Ump range for better performance. This requires a station with several serially connected modules
Model -. 2kVA / 3kVA
Optimal Ump - 30B
range Ump - 30B ~ 32B
Write the first review
A new review or comment
Sign in with
Rate this item
Send
14 134.00 UAH
В наличии
Sign in to
see discount

Self-delivery, "UkrPochta", "Nova pochta" or convenient carrier.
Courier in Kiev.

Bank transfer ( our company for VAT )
Cash on delivery
Credit Card in privat24, LiqPay
Through cash or self-service terminal Privatbank

The warranty from the manufacturer between 1 and 5 years.

 

According to the current legislation of Ukraine.

Consultation by phone:

+38 (044) 585-64-94
+38 (097) 585-25-00
+38 (095) 585-25-00
+38 (093) 585-25-00

Features
Electric power, W 1600
Price 14134.00
Up